<LOGO>
FM Transmitter Measurement Report
Created: 2025-11-06 01-37-52
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 60 dBuV YLEX
Pilot RDS Phase Difference
7.2 kHz 2.2 kHz 69 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 63 kHz 19040 0,7721
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,3 dBr 3,86 dBr 4,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"YLEX " 6202 10 (Pop M) 0 1 1 1 1:37, 6.11.2025
RT
-
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6201, 6203, 6207, 6205
FM Scope Max at: 63 kHz MIN: 9 kHz % above 76 kHz: 0,7721 Acquired: 2025/11/06 1.36.47 Total samples: 19040 Equivalent time: 0:15:52 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 4,7 dBr MIN: 0,3 dBr AVE: 3,86 dBr % above 12,2 dBr: 0,0 Last value: 4,4 dBr (2025/11/06 1.36.47) 01.22 01.24 01.26 01.28 01.30 01.32 01.34 01.36 0 2 4 Pm [dBr]